Safety of Navigation & Bridge Watchkeeping

BNWAS Bridge Watch Alarm System: SOLAS V/19 & MSC.128(75) Guide

The Bridge Navigational Watch Alarm System (BNWAS) is a fundamental electronic safety safeguard mandated under SOLAS Chapter V Regulation 19.2.2.3 and IMO Resolution MSC.128(75) (Performance Standards for BNWAS). Designed to detect watchkeeper incapacitation resulting from fatigue, medical emergency, or falling asleep on watch, the system enforces a strict three-stage progressive alert sequence. In 2014, the IMO issued MSC.1/Circ.1474, recommending that BNWAS operate in 'Manual ON' mode at all times when underway, eliminating dangerous gaps caused by automatic heading-control interlocks.

Updated · Written by SeaReady in our own words. Not affiliated with OCIMF, RightShip, CDI, any MoU or any administration — always check the current official documents.

1. Regulatory Framework: SOLAS V/19 & IMO Resolution MSC.128(75)

Single watchkeeper operations at night and during long ocean passages create severe risks of acute fatigue, microsleep, and sudden physical incapacitation. Under SOLAS Chapter V Regulation 19.2.2.3, all cargo ships of 150 gross tonnage and upwards and all passenger ships irrespective of size must be fitted with an approved Bridge Navigational Watch Alarm System (BNWAS).

The purpose of the system is strictly defined by IMO Resolution MSC.128(75): to monitor bridge activity and detect operator disability which could lead to marine casualties. The system enforces periodic confirmation of alertness from the Officer of the Watch (OOW); if the officer fails to acknowledge the system within a preset dormant period, an escalating series of visual and audible alarms alerts first the bridge, then the Master and backup officers, and ultimately the entire crew.

2. The Progressive Alert Sequence: Timing Cycles & Alarm Stages

The core architecture of BNWAS relies on an unyielding, progressive timing cycle designed to awaken an inattentive officer or summon backup before the vessel runs into danger:

Alarm Progression StageOperational Time WindowVisual / Audible ManifestationRegulatory Citation & Safety Intent
Dormant Period (Td)3 to 12 minutes (Master set)The silent countdown period while the Officer of the Watch (OOW) is actively carrying out bridge navigation duties. Reset by any verified watch activity.IMO Res. MSC.128(75) § 4.1. Master controls dormant setting (typically 3–5 min in heavy traffic / pilotage; up to 12 min in open ocean under clear conditions).
Stage 1: Bridge Visual & Audible Alarm15s visual flashing -> 15s bridge toneAt the end of Td, a flashing visual indicator appears on the bridge for 15 seconds. If unreset, a distinctive audible alarm sounds on the bridge for an additional 15 seconds.MSC.128(75) § 4.1.2. The visual indication must be clearly visible from all operational bridge watch positions without impairing night vision.
Stage 2: Master & Backup Officer CabinsTransfers 15s after Stage 1 audible alarmIf Stage 1 is not reset within 15 seconds of the bridge tone sounding, an audible alarm transfers directly to the Master's and/or designated backup officer's cabins.MSC.128(75) § 4.1.3. Must produce a tone distinct from all other shipboard alarms with sufficient volume to awaken resting officers.
Stage 3: General Crew & Public Rooms AlarmTransfers 90 to 180s after Stage 2 alarmIf Stage 2 is not reset within 90 to 180 seconds, an audible alarm sounds in crew messrooms, duty mess, officer lounge and public rooms to summon emergency assistance.MSC.128(75) § 4.1.4. On non-passenger ships, Stage 2 and Stage 3 may sound simultaneously in officer cabins and crew areas if configured.
Emergency Call FacilityImmediate manual push-button activationProvides an instantaneous means on the bridge for the OOW to trigger the Stage 2/3 alarms without waiting for the dormant period to lapse.MSC.128(75) § 4.3. Used in sudden medical crises, piracy threats, bridge intruder alerts, or impending collision emergencies.

Key-Switch Security & Access Control: Under paragraph 4.2.2 of Resolution MSC.128(75), the means of selecting operational modes and the duration of the dormant period (Td) must be protected by security access controls (a physical key-switch held exclusively by the Master or a password-protected PIN). Leaving the physical key inserted in the BNWAS unit on the bridge is a frequent PSC observation.

3. Operational Modes & The MSC.1/Circ.1474 'Manual ON' Imperative

Resolution MSC.128(75) originally provided three operational modes: Automatic, Manual ON, and Manual OFF. However, real-world casualty investigations revealed a fatal flaw in the Automatic mode:

Operational ModeFunctional Operational StatusSteering / Autopilot InterfaceRegulatory Status & Vetting Requirement
Manual ON (Mandatory Underway Mode)Operates continuously 24/7 at seaSystem is fully active at all times regardless of steering mode (autopilot, track control, or manual hand steering). Mandatory under MSC.1/Circ.1474.IMO MSC.1/Circ.1474 & PSC Guidelines. Guarantees watchkeeper alertness even when hand steering in traffic schemes, pilot waters, or adverse weather.
Automatic Mode (Interlock Limitation)Active only when autopilot / TCS is engagedSystem turns on when heading/track control is engaged and shuts off when hand steering. MSC.1/Circ.1474 explicitly cautions against using this mode.SOLAS V/19.2.2.3 & MSC.128(75) § 4.2.1. Hand steering during critical manoeuvres left the bridge unmonitored, leading to numerous groundings.
Manual OFF (In Port & Secure Berth)Completely inhibited during port stayUsed exclusively when the vessel is safely moored alongside, in dry dock, or laid up with no active navigational watch requirement.MSC.128(75) § 4.2.1. Key-switch or password protected. Must be switched to Manual ON prior to casting off lines and commencing passage.
VDR / S-VDR Interface & LoggingIEC 61996-1 & Res. MSC.333(90)BNWAS operational status (Manual ON/OFF/Auto), reset inputs, pre-alarms, and transfer alarm activations must be recorded continuously by the VDR.Mandatory under SOLAS Reg. V/20 & MSC.333(90). Casualty investigators correlate VDR BNWAS reset logs with radar/ECDIS anti-collision actions.
Emergency Power Supply FailoverAutomatic backup & power failure alarmPowered from main bridge electrical switchboard with automatic failover to the emergency source of electrical power or dedicated UPS battery.MSC.128(75) § 6. Failure of main power must trigger an immediate malfunction alarm on the bridge and maintain operation for at least 6 hours.

The Danger of Automatic Mode: In Automatic mode, the BNWAS is connected to the autopilot or track control system, deactivating whenever hand steering is engaged. Several high-profile groundings occurred because the helmsman was dismissed to duties on deck while the OOW took manual steering, and subsequently fell asleep without the BNWAS active. Consequently, in MSC.1/Circ.1474, the IMO strongly recommended that BNWAS operational mode selection should remain in Manual ON whenever the ship is underway at sea.

4. Reset Devices, Sensor Placement & Anti-Tampering Standards

The placement and mechanism of BNWAS reset devices must facilitate active watchkeeping without encouraging laziness or mechanical bypasses:

  • Reset Button Locations: Push-buttons must be fitted at key conning positions within the wheelhouse, at the chart table, and on both bridge wings (MSC.128(75) § 4.1.1). Reset devices must be accessible only from areas of the bridge providing a proper lookout.
  • Bridge Console Integration: Interfaced equipment (such as adjusting radar gain, interacting with ECDIS route menus, or pressing autopilot heading confirmation) may generate valid reset inputs if approved by the Administration.
  • Passive Infrared (PIR) Motion Sensors: Where PIR sensors are fitted, they must be calibrated to detect natural watchkeeper movement across the wheelhouse while avoiding blind spots or spurious resets caused by heater blowers or sun glare.
  • Prohibition of Mechanical Bypasses: Using weighted pendulums, desk fans, or taped-down switches to create false resets violates SOLAS V/19 and will result in immediate PSC detention under ISM Code safety management deficiencies.
  • Emergency Call Button: A dedicated emergency call facility must be positioned on the centre conning console, enabling the OOW to immediately sound Stage 2/3 backup alarms if threatened by unauthorized boarders, medical collapse, or extreme navigational hazards.

5. VDR Interfacing, Power Supply & Top PSC Deficiencies

Port State Control inspectors test BNWAS operational readiness under Tokyo MOU, Paris MoU, and USCG deficiency code 10127 (BNWAS):

  • Full Operational Staging Test: Inspectors will request the OOW to arm the BNWAS, allow the dormant period to lapse, and verify that Stage 1 visual flashing occurs, followed 15s later by the bridge audible tone, and 15s later by the remote Master/officer cabin alarm.
  • Cabin Buzzer Audibility: Verify that the alarm buzzer in the Master's and Chief Officer's cabins produces an audible sound level of >= 75 dB(A) over the noise of running cabin air conditioning or ventilation blowers.
  • Bridge Wing Button Weatherproofing: Bridge wing reset buttons must maintain watertight integrity (IP56 minimum) and operate smoothly in freezing or wet conditions.
  • VDR Interfacing (Res. MSC.333(90)): Confirm that BNWAS mode changes, reset pulses, and alarm transfers are logged in the VDR and verified during the annual VDR Performance Test.
  • Power Supply & Battery Backup: Verify that failure of the main 220V/110V bridge power supply automatically trips to 24V DC emergency power or dedicated UPS battery with audible bridge power-loss notification.

Questions seafarers ask

Which ships are legally required to carry a compliant BNWAS under SOLAS Regulation V/19?

Under SOLAS Regulation V/19.2.2.3, a Bridge Navigational Watch Alarm System (BNWAS) is mandatory for: (1) all cargo ships of 150 gross tonnage and upwards, and (2) all passenger ships irrespective of size. The system must meet the Performance Standards adopted by IMO Resolution MSC.128(75) and be connected to the vessel's Voyage Data Recorder (VDR) under Resolution MSC.333(90).

Why do Port State Control and vetting inspectors require BNWAS in "Manual ON" mode rather than "Automatic"?

Under IMO Circular MSC.1/Circ.1474, the IMO Maritime Safety Committee determined that operating BNWAS in "Automatic" mode (interlocked only with the autopilot / track control system) compromises navigational safety. When a vessel enters manual hand steering—such as in traffic separation schemes, narrow channels, port approaches, or during collision avoidance manoeuvres—Automatic mode inhibits the alarm, leaving the bridge unmonitored during the most critical phases of navigation. Therefore, PSC inspectors and vetting regimes (SIRE 2.0 / RightShip RISQ) require BNWAS to be switched to "Manual ON" whenever the ship is underway.

What is the precise alarm sequence and timing of BNWAS Stages 1, 2, and 3 under MSC.128(75)?

Under MSC.128(75) § 4.1: (1) Dormant Period (Td) runs for 3 to 12 minutes as set by the Master; (2) At the end of Td, Stage 1 visual flashing appears on the bridge for 15 seconds; (3) If unreset, Stage 1 audible alarm sounds on the bridge for 15 seconds; (4) If still unreset, Stage 2 audible alarm sounds in the Master's and/or backup officer's cabin; (5) If unreset after 90 to 180 seconds, Stage 3 audible alarm sounds in public crew locations and messrooms.

Can mechanical devices or oscillating fans be used to trigger BNWAS motion detectors?

No. Using oscillating fans, suspended cardboard, swinging objects, or tape over motion sensors to defeat BNWAS is a serious statutory violation and a major grounds for Port State Control detention under ISM Code deficiency 15150. Under MSC.128(75) § 4.1.1, reset facilities must require physical human interaction or genuine navigational console manipulation from positions providing a proper lookout.

How must BNWAS be integrated with the ship's Voyage Data Recorder (VDR)?

Under IMO Resolution MSC.333(90) and IEC 61996-1, the VDR must record BNWAS operational mode status (Manual ON, Manual OFF, Automatic), reset trigger events, pre-alarm activations, and Stage 1/2/3 alarm states. During maritime casualty investigations, VDR logs are analysed to establish whether the Officer of the Watch was actively alert and resetting the system prior to any incident.

Open Navigation & Bridge Checklist

Review SOLAS V/19 BNWAS, ECDIS, radar, magnetic compass and GMDSS bridge equipment checks for PSC.

  • Offline SIRE 2.0, RightShip RISQ and PSC checklists
  • AI mock inspector and orals examiner
  • AI photo review of defects and ship-work photos
  • Rest-hour planner and record-book tools

Crew $39.99/mo · Officer Pro $99.99/mo · Ship licence $899/mo per ship + 5% sales tax

14-day free trial, no card needed. Works offline at sea once installed.

Related guides

All 68 guides →