Fire Protection & Escape Route Safety
Fire Control Plan: SOLAS II-2/15, IMO Res. A.1116(30) & ISO Signs Guide
Updated · Written by SeaReady in our own words. Not affiliated with OCIMF, RightShip, CDI, any MoU or any administration — always check the current official documents.
1. Statutory Architecture: SOLAS II-2/15.2.4 & General Arrangement Plans
A ship's Fire Control Plan is not merely an engineering drawing; it is a legally binding operational document that coordinates shipboard firefighting strategy and informs emergency services during a casualty. Under SOLAS Chapter II-2 Regulation 15.2.4, general arrangement plans must be permanently exhibited for the guidance of the ship's officers in prominent, illuminated locations (such as the navigation bridge, ship's office, engine control room, and main alleyways).
Alternatively, at the discretion of the flag Administration, the detailed fire safety information may be presented in a booklet form, provided a copy is supplied to each officer and one copy is accessible at all times on board in an approved position. The plan must detail the exact positions of structural boundaries, extinguishing appliances, detection zones, and remote shutdown controls:
| Fire Safety System Category | Key Graphical / Technical Elements | Detailed Scope of Exhibited Information | Statutory Basis & Verification |
|---|---|---|---|
| Structural Fire Divisions & Boundaries | "A" class & "B" class divisions | Clear demarcation of main vertical zones, fire boundaries, watertight and fire doors, self-closing doors, hold bulkheads, and accommodation boundaries. | SOLAS Reg. II-2/15.2.4.1 & II-2/9. Enables officers and shore firefighters to assess thermal containment and boundary cooling requirements. |
| Detection, Alarms & Manual Call Points | Zones, loops, smoke/heat heads & call points | Location of central fire detection panels, sub-panels, addressable detector loops, smoke detectors, flame/heat sensors, and manual fire alarm break-glass units. | SOLAS Reg. II-2/7, FSS Code Ch. 9 & ISO 17631. Critical for immediate identification of fire zone origins from navigation bridge and fire stations. |
| Fire Extinguishing Appliances & Systems | Pumps, hydrants, hoses, fixed systems & portables | Positions of main fire pumps, emergency fire pump, sea suctions, isolation valves, hydrants, hose boxes, international shore connection, and portable extinguishers. | SOLAS Reg. II-2/10, FSS Code Ch. 2–8 & ISO 17631. Identifies fixed CO2 / water-mist / foam release stations, cylinder rooms, and local actuators. |
| Ventilation Dampers & Remote Emergency Stops | Fans, dampers, fuel trips & quick-closing valves | Locations of supply and exhaust ventilation fans, fire dampers, remote closing controls, machinery space fuel quick-closing valves, and boiler stop valves. | SOLAS Reg. II-2/5.2.1.1, II-2/15.2.4.1 & ISO 17631. Numbering on the plan MUST correspond exactly with physical brass tags on damper operating handles. |
| Means of Escape & Muster Stations | Primary/secondary escape trunks, stairs & doors | Escape routes from machinery spaces, cargo holds, public rooms, and accommodation blocks, leading to embarkation stations and muster areas. | SOLAS Reg. II-2/13, FSS Code Ch. 13 & Res. A.1116(30). Identifies emergency escape breathing apparatus (EEBD) lockers and low-location lighting paths. |
2. Signage Evolution: Resolution A.1116(30), ISO 7010 & ISO 24409
For decades, maritime safety signage relied on IMO Resolution A.760(18) symbols. However, differences between civil building codes and maritime symbols created dangerous confusion during emergencies. To eliminate discrepancies, the IMO Assembly adopted Resolution A.1116(30) (Escape Route Signs and Equipment Location Markings):
| Signage Standard / Requirement | Application Threshold & Effective Date | Graphic Standard & Functional Scope | Statutory Mandate & Inspection Focus |
|---|---|---|---|
| IMO Res. A.1116(30) / ISO 7010 & 24409 | New ships (1 Jan 2019+) & repairs/refits | Harmonized international standard for escape route signs, fire equipment locations, and life-saving appliance markings across maritime and civil sectors. | Mandatory under SOLAS II-2/15.2.4 & Res. A.1116(30). Replaced legacy Res. A.760(18) symbols. Green running person, standardized red fire gear icons. |
| External Fire Plan Weathertight Container | Permanently mounted outside deckhouse | Duplicate set of up-to-date fire control plans or booklet stored in a prominently marked weathertight enclosure outside the superstructure for shore firefighters. | SOLAS Reg. II-2/15.2.4.2 & MSC/Circ.451. Red weathertight cylinder marked with ISO 17631 fire plan symbol. Must open easily without tools. |
| Low-Location Lighting (LLL) System | Passenger ships (>36 pax) & ro-ro passenger | Photoluminescent or electrically powered guidance lines fitted <= 0.3 m above deck along all escape routes, stairs, and exit doors to penetrate dense smoke. | SOLAS Reg. II-2/13.3.2.5.1 & FSS Code Ch. 11. Photoluminescent strips must be tested annually for luminance (>= 15 mcd/m² at 10m, >= 2 mcd/m² at 60m). |
| Graphical Symbols for Fire Control Plans | IMO Res. A.952(23) / ISO 17631:2002 | Standardized graphical symbols used directly on exhibited shipboard fire plans and booklets for fire protection, life-saving appliances and escape routes. | Ensures universal comprehension by international ship officers, classification surveyors, PSC inspectors, and shore-side municipal fire brigades. |
| Language & Translation Requirements | Ship working language + English or French | Exhibited fire control plans, booklets, legend symbols, and operational instructions must be in ship's working language, with English or French translation. | SOLAS Reg. II-2/15.2.4.1. Avoids language barriers during emergency multi-agency response, joint salvage, or Port State Control inspections. |
Mixed Standards Hazard: A common Port State Control detention trap occurs when existing vessels undergo partial signage replacement and mix legacy A.760(18) symbols with new A.1116(30) / ISO 7010 signs along the same escape trunk. If signage is renewed, the entire escape route or compartment must follow a single consistent standard, and the shipboard Fire Control Plan legend must accurately reflect the specific symbols installed.
3. External Weathertight Container: MSC/Circ.451 & Shore-Side Readiness
When a ship catches fire in port, municipal shore firefighters board an unfamiliar vessel in thick smoke and intense heat. Under SOLAS Regulation II-2/15.2.4.2 and IMO MSC/Circ.451, a duplicate set of Fire Control Plans or fire safety booklets must be permanently stored in a prominently marked weathertight enclosure outside the deckhouse:
- Physical Construction & Location: Typically a cylindrical metal or heavy-duty plastic container painted bright signal red, mounted on an exterior bulkhead immediately adjacent to the primary gangway or embarkation access point.
- Prominent Marking: Marked clearly with the ISO 17631 / A.1116(30) graphical symbol for "Fire Control Plan" (a red drawing icon depicting a ship profile and fire axes). Lettering "FIRE PLANS" should be in contrasting white.
- Weathertight Integrity: The canister lid or door must be fitted with an intact neoprene or rubber gasket to prevent rainwater, salt spray, and atmospheric moisture from soaking and destroying the paper plans inside.
- Tool-Free Access: The container MUST be capable of being opened easily and immediately by hand without keys, padlocks, wrenches, or special tools. Locking the external fire plan cylinder is a major detention item.
- Up-to-Date Contents: The plan inside must be identical to the wheelhouse plan, reflecting all recent alterations, current crew muster list roles, dangerous goods manifests (if in port), and stability data summaries.
4. Low-Location Lighting (LLL) & Escape Trunks: FSS Code Ch. 11
In a major fire, thermal buoyancy causes superheated toxic smoke to fill the upper 1.5 to 2.0 metres of corridors and stairwells, blinding standard ceiling-mounted emergency lights and rendering bulkhead signs invisible. Low-Location Lighting (LLL) ensures that evacuees crawling beneath the smoke layer can trace an unbroken illuminated path to safety:
- Mandatory Carriage: Required on all passenger ships carrying more than 36 passengers (SOLAS II-2/13.3.2.5.1) and all ro-ro passenger ships.
- Installation Geometry: Continuous photoluminescent strip or electrically powered light track fitted not more than 0.3 metres above the deck along all escape corridors, stairways, and exits.
- Door & Exit Marking: Fire exits, escape hatch ladders, and emergency doors must be outlined with LLL markings, with door handles marked to indicate opening mechanisms.
- Luminance Performance (FSS Code Ch. 11 & Res. A.752(18)): Photoluminescent strips must maintain >= 15 mcd/m² after 10 minutes of darkness, and >= 2 mcd/m² after 60 minutes.
- Annual Survey & Certification: Annual measurement of photoluminescent luminance must be conducted using a calibrated photometer by an approved service supplier and kept with Class survey records.
5. Plan Maintenance, Damper Verification & Top PSC Deficiencies
Port State Control inspectors scrutinize Fire Control Plans under Paris MoU, Tokyo MOU, and USCG deficiency code 07105 (Fire safety documentation). Any discrepancy between the drawing and shipboard reality raises immediate suspicions regarding safety management system (SMS) integrity:
- Damper Tagging & Plan Cross-Checks: Every fire damper on deck must carry a physical, weather-resistant label (e.g. "FD-ENG-01") that matches the plan legend exactly. Numbering errors or unlabelled dampers are universally penalized.
- Operational Testing of Dampers: During PSC inspections, officers will be required to operate dampers, verifying free fall of counterweights, intact fusible links, and full internal flap closure.
- Remote Fuel Stops & Quick-Closing Valves: Verify that emergency stop stations (boiler trips, fuel transfer pump stops, lub oil pump trips, quick-closing valve pull handles) match the symbols on the Fire Control Plan.
- International Shore Connection: Ensure the international shore connection flange, bolts, gasket, and spanners are stowed in the exact locker designated on the plan.
- Damp or Illegible External Plans: Check the external fire plan cylinder weekly. Wet, stuck, or faded plans represent an immediate Form B deficiency and undermine port safety coordination.
Questions seafarers ask
Where must the external duplicate Fire Control Plan be stowed under SOLAS II-2/15.2.4.2?
Under SOLAS Regulation II-2/15.2.4.2 and IMO MSC/Circ.451, a duplicate set of fire control plans or an equivalent booklet must be permanently stored in a prominently marked weathertight enclosure outside the deckhouse for the assistance of shore-side fire-fighting personnel. This container is typically a bright red weathertight cylindrical canister mounted on the exterior bulkhead near the primary accommodation access gangway, clearly marked with the IMO fire plan graphical symbol and easily openable without tools or keys.
Which ships are legally required to comply with IMO Resolution A.1116(30) safety signage?
IMO Resolution A.1116(30) applies to: (1) all ships constructed on or after 1 January 2019, and (2) existing ships undergoing repairs, alterations, modifications, and outfitting within the scope of SOLAS Chapters II-2 and/or III that involve replacement or addition of signage. The resolution harmonizes maritime signage with international standard ISO 7010, replacing legacy Resolution A.760(18) symbols with modern standardized graphical icons (such as the green running person with directional arrow for emergency escapes).
What is the most frequent PSC deficiency regarding shipboard ventilation fire dampers and Fire Control Plans?
The most frequent PSC deficiency is a discrepancy between the damper numbering and locations shown on the Fire Control Plan and the physical brass or engraved labels fitted on the dampers on deck. Furthermore, inspectors test whether dampers close fully, whether counterweights drop freely without sticking, whether remote pneumatic/manual damper closures operate, and whether open/shut visual indicators align with the actual internal damper blade position.
What are the technical luminance requirements for photoluminescent Low-Location Lighting (LLL)?
Under SOLAS Regulation II-2/13.3.2.5.1, FSS Code Chapter 11, and IMO Resolution A.752(18) / ISO 15370, photoluminescent low-location lighting strips fitted on passenger ships carrying over 36 passengers must be installed not more than 0.3 m above the deck along escape routes and must produce a minimum luminance of 15 mcd/m² ten (10) minutes after the removal of all external light sources, and at least 2 mcd/m² after sixty (60) minutes. LLL systems must undergo annual onboard luminance testing by a qualified specialist.
What language requirements apply to shipboard Fire Control Plans and booklets under SOLAS?
Under SOLAS Regulation II-2/15.2.4.1, the Fire Control Plan and any accompanying booklets must be written in the working language of the ship. If the working language is neither English nor French, a full translation into either English or French must be incorporated directly onto the exhibited plans, legends, and equipment booklets so that visiting inspectors, pilots, and municipal fire teams can read all operational descriptions without ambiguity.
Open Fire Safety & FFA Checklist
Review SOLAS II-2 fire control plans, safety signage, fire dampers, EEBD lockers and LSA/FFA checks for PSC.
- Offline SIRE 2.0, RightShip RISQ and PSC checklists
- AI mock inspector and orals examiner
- AI photo review of defects and ship-work photos
- Rest-hour planner and record-book tools
Crew $39.99/mo · Officer Pro $99.99/mo · Ship licence $899/mo per ship + 5% sales tax
14-day free trial, no card needed. Works offline at sea once installed.
Related guides
- LSA & FFA maintenance intervals checklistWeekly, monthly, annual and 5-yearly LSA/FFA maintenance intervals under SOLAS III/20 and MSC.1/Circ.1432.
- Gangway, pilot ladder & ISPS access checklistSOLAS II-1/3-9 gangway/accommodation ladder, SOLAS V/23 pilot transfer (MSC.576(110)) and ISPS access checks.
- Enclosed space entry checklistIMO MSC.581(110) atmosphere limits, SOLAS XI-1/7 gas meters, the permit and 2-monthly drills.
- SOLAS crew familiarisation & onboard training guideSOLAS III/19 & STCW pre-sailing familiarisation, 2-week LSA/FFA training, 2-month cycles, and ECDIS type-specific.